Rychlá dodávka pro úplnou výměnu bezpečnostního senzoru

Domů / vše / Safety Products / Laser Scanning Radar /

100 m Measurement Safety|Laser Scanning Radar|DADISICK

100 m Measurement Safety|Laser Scanning Radar|DADISICK
100 m Measurement Safety|Laser Scanning Radar|DADISICK100 m Measurement Safety|Laser Scanning Radar|DADISICK100 m Measurement Safety|Laser Scanning Radar|DADISICK100 m Measurement Safety|Laser Scanning Radar|DADISICK100 m Measurement Safety|Laser Scanning Radar|DADISICK

100 m Measurement Safety|Laser Scanning Radar|DADISICK

kategorieLaser Scanning Radar
Obchodní značkaDADISICK
SpecifikaceLD-100R
Sensing range:0.1 m ~ 100 m
Scanning frequency:10 Hz / 20 Hz
Scanning angle range:360°
Angular resolution0.05°/ 0.1°
Light source:Infrared laser (905 nm)
Laser safety level:Class 1 (GB7247.1-2012, Eye-safe IEC)
Čas editace2024/11/22
Více detailů
Basic Information
Product number
Measurement laser scanning radar
Model
LD-100R
Output
I/O output & Ethernet output
Features
Light source
Infrared laser (905 nm)
Laser safety level
Class I (GB 7247.1-2012, Eye safe IEC)
Laser spotlight diameter
10 mm
Laser spotlight scan angle
2.4mrad(H) ╳ 10 mrad(V)
Scanning angle range
360°
Scanning frequency
10 Hz / 20 Hz
Scanning Angular Resolution
0.05°/ 0.1°
Sensing range
0.1 m ~ 100 m
10% reflectivity range
20 m
Outdoor performance
Anti-dusty, Anti-sunlight
Rain, fog and smoke penetration
Supported
Device Interface
Ethernet
Rate: 10/100 Mbps
Network protocol: TCP/IP
Function: Device configuration / measurement data output
I/O Input
Input port: 4
Type: Level input
High level range: DC 10 V - 30 V
Low level range: DC 0 V - 0.7 V
Preset functions: power saving and life extension control, effective level: high level
I/O Output
Input port: 4
Type: PNP/NPN switch output
Switching voltage: supply voltage
Power on status: off
Preset function: device ready, valid state: on
Indicator light
Quantity: 4 
Definition: PWR (power supply)
LNK (Ethernet)
ERR (device alarm: dirty/blocked/dense fog, high and low temperature)
HTR (normal measurement)
Mechanical/electronic paramete
Operating voltage
DC 10 V – 30 V
Power dissipation
6W@DC24V
Degree of protection (IP)
IP65(GB 4208-2008)
Insulation resistance
1MQ(GB 16796-2009,5.4.4)
Electric strength
0.5KV(GB 16796-2009,5.4.3)
Dimension (L ╳ W ╳ H)
97 X 97 X 90 (mm)
Weight
0.7 kg
Working Environment Standard
Electrostatic discharge
6 KV (GB/T 17626.2-2006, class 3) IEC
Fast bursts
1 KV (GB/T 17626.4-2008, class 2) IEC
Electromagnetic field radiation immunity
GB/T 17626.3-2006, class 2
Surge immunity
GB/T 17626.5-2008
Power interface: 1.2 / 50 μs, 2 KV / 1 KA (class 3)
Ethernet interface: 10 / 700 μs, 1 KV / 25 A (class 2)
I/O interface: 1.5 / 50 μs, 0.5 KV / 0.25 KA (class 1)
Impact
● Single impact
● Continuous impact
GB/T 2423.5
15g, 11 ms
10g, 16 ms
Vibration
● Frequency range
● Amplitude
GB/T 2423.10
10 Hz ~ 150 Hz
5 g
Humidity
93%,+40℃,2h (GB/T 2423.3)
Operating temperature range
-10℃ ~ +50℃
Storage temperature range
-30℃ ~ +70℃
Ambient illumination range
0 lux ~ 80,000 lux
1: Refers to a ф 100mm cylindrical reflector, the reflective surface material has a diffuse reflectance of 1000%, and the reflective surface length is 600mm.
DOCUMENTS & DOWNLOADS
Catalogue

LD-100R Data Sheet
3D
LD-100R.3D-STP
Certificate
CE Certificate of LiDAR Scanner
ECM Certificate of Safety LiDAR Scanner
Hodnocení
  • Loading ...
Související produkty
    Poslat dotaz
    *Email
    Vaše celé jméno
    *Titul
    *Obsah
    Nahrát
    • Podpora pouze .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximálně 20 milionů